The thermal conductivity tester (plate method) is mainly used to measure the thermal conductivity of refractory fibers, insulation boards, insulation bricks and other insulation materials with a temperature of 200-1300℃ and a thermal conductivity of 0.01-3.0 W/(m·K) and a variety of amorphous refractory materials. The flat plate thermal conductivity tester is mainly composed of a heating furnace, a microcomputer measurement and control system, a cooling circulating water system, a calorimeter system and a constant pressure water system.

Phone: +86 13213665267
Product Details

The thermal conductivity tester (plate method) is mainly used to measure the thermal conductivity of refractory fibers, insulation boards, insulation bricks and other insulation materials with a temperature of 200-1300℃ and a thermal conductivity of 0.01-3.0 W/(m·K) and a variety of amorphous refractory materials.

The flat plate thermal conductivity meter meets the YB/T4130 test standard. According to the basic principle of the Fourier one-dimensional plate stable heat conduction process, it measures the heat carried away by the water in the calorimeter after the one-dimensional heat flow passes through the hot surface of the sample to the cold surface in a steady state. The heat Q is proportional to the thermal conductivity λ and inversely proportional to the temperature difference △T of the hot surface of the sample. This instrument obtains the thermal conductivity λ by measuring Q and △T.

The flat plate thermal conductivity meter equipment is mainly composed of a heating furnace, a microcomputer measurement and control system, a cooling circulating water system, a calorimeter system and a constant pressure water system.

Thermal Conductivity Tester (Plate Method) Technical Parameters

Model/Specification

PBDR—HT13A

PBDR—HT15A

PBDR—HT13

Working Temperature(℃)

1300

1500

1300

Thermal Conductivity,W/m.k

0.01-3.0

Size of Sample(mm)

φ180×(20±5)

Measuring Accuracy,%

3

Testing Mode

Automatic

Manual Operation


Single layer multi-point
(Single Layer Multi-point)

Multi-layer and multi-point

(Multi-layer and Multi-point)

Product Inquiry

Product Name:Thermal Conductivity Tester (Plate Method)

Service · Development · Cooperation · Win Win

Contact Us

Person:Manager Zeng +86 13213665267 +86 13949209449

Person:Manager Liu +86 18623769066

Email:heatest@qq.com

Address:Inside the Zhisheng Science and Technology Institute, Luoyi Road, High tech Zone, Luoyang City

Application
曾经理

Manager Zeng

曾经理

Manager Zeng

刘经理

Manager Liu

抖音二维码

Tiktok QR code

© Luoyang Heatest Instrument Equipment Co., Ltd Power by:ShangXian Sitexml

Home

Tel

Contact

Top