Common faults of high temperature bending test machines include temperature control system failure, loading system failure, control system failure, high temperature cavity damage, electrical system failure, etc. It is recommended to formulate a periodic inspection and maintenance plan to ensure the ...
In the field of material mechanical properties testing, the high temperature flexural tester is a precision testing equipment used to evaluate the flexural properties of materials under high temperature environments. This tester needs to run for a long time under high temperature environments, so it is inevitable that some faults will occur. Timely discovery and correct handling of these faults are particularly important to ensure the accuracy of test data and the service life of instruments and equipment. In this article, HEATE Xiaobian introduces the common faults of high temperature flexural testers and corresponding treatment methods.
1. Temperature control system failure
The temperature control system is the core component of the high temperature flexural tester, and its normal operation directly affects the reliability of the test. Common faults include large temperature fluctuations, slow heating rate, and temperature overheating.
Treatment method: Check whether the heating element is aging or damaged, check whether the temperature sensor has too large accuracy deviation, and check whether there are problems with the control system software and hardware. If necessary, replace the relevant components and recalibrate the system. At the same time, pay attention to maintaining the cleanliness of the furnace to avoid impurities affecting the heat transfer performance.
2. Loading system failure
The loading system is a key component for applying the test load, and failures will affect the accuracy of the test results. Common faults include loading rod jamming, unsmooth movement, load reading drift, etc.
Solution: Check whether the loading rod is worn or contaminated, clean or replace the slider and guide rail. Check the line connection and calibration status of the loading sensor. For loading rod jamming, try adding high-temperature lubricant. Ask professionals to perform system maintenance and debugging if necessary.
3. Control system failure
The control system integrates the operation interface, data acquisition and test control functions, and its stability is particularly important for the test. Common faults include system freeze, data loss, communication interruption, etc.